RELEKOESTUSTesting services by Avitor sähkö OyContact details
AVITOR SÄHKÖ OY · TESTING SERVICESCONFIDENCE THROUGH MEASUREMENT.

Confidence.
Through relay testing.

Testing services are provided by Avitor sähkö Oy. Verify protection performance through measurement. Protection relay testing, relay programming and primary injection testing — from commissioning to maintenance.

Explore our services
Blue solar panels and electrical equipment containers at a solar farm
FOR ELECTRICAL PROFESSIONALS
WHEN PROTECTION HAS TO WORK.

Measured performance.
Clear results.

Photo: Sungrow EMEA / Unsplash
AS ENERGY EVOLVES.
CONFIDENCE MATTERS.
Substations & industry
Solar & wind power
Battery storage
TESTING SERVICES

The right tests.
For your site.

New commissioning, periodic maintenance or modified protection. We agree on the work that gives you the answers you need.

TESTING & DOCUMENTATION

Protection relay testing

Verification of protection relay operation during commissioning, periodic maintenance and after modifications. We measure operating values and times and document the results within the agreed scope.

  • Commissioning
  • Periodic testing
  • Modifications
SETTINGS & CONFIGURATION

Relay programming

Protection relay settings and configuration according to the site's approved protection design. Changes are documented and operation is verified within the agreed scope.

  • Entering settings
  • Configuration
  • Documenting changes
PRIMARY CURRENT INJECTION

Primary injection testing

Primary current injection complements relay testing. The scope of testing for the site's measurement and protection chain, and the suitability of the equipment, are established in advance.

  • Current injection
  • Measurement chain
  • Site-specific delivery
FROM MEASUREMENT TO INSIGHT

Know what was tested.
And how it performed.

Testing gives you more than a completed task. You receive documented results to support commissioning, maintenance and further action.

See the testing process
WHAT YOU RECEIVE

Test report

01
Scope tested

Relays, settings and the agreed scope of testing.

02
Measured results

Operating values and times compared with the settings.

03
Findings and deviations

A clear basis for any further action.

The documentation scope is agreed as part of the work.
THE EQUIPMENT WE USE

Accuracy starts with
the right tools.

Kingsine and Megger. Three complementary instruments for protection relay testing and primary current injection.

Kingsine KFA320 relay test setPhoto: Kingsine
KINGSINE

KFA320

Versatile relay testing

A compact test set for multiphase protection relay testing. IEC 61850 testing is an optional function.

Analogue outputs
6 × I / 4 × U
Digital testing
IEC 61850 (optional)
Application
Multiphase relay testing
Manufacturer's product information (opens in a new tab)
Megger SVERKER 900 relay test setPhoto: Megger
MEGGER

SVERKER 900

Three-phase testing

A relay and substation test system for testing protection in distribution networks and industrial installations.

Testing
Three-phase
Analogue outputs
3 × I / 4 × U
Application
Secondary injection testing
Manufacturer's product information (opens in a new tab)
Megger CSU600A current injection unit from the CSU 600 product familyPhoto: Megger · CSU600A
MEGGER

CSU 600

Primary current injection

A current injection unit for primary testing. Complements relay testing according to the site requirements and agreed test plan.

Method
Primary current injection
Testing
Primary injection testing
Delivery
Site-specific
Manufacturer's product information (opens in a new tab)

The right method matters.We establish the right equipment and scope of testing for your site.

FROM PLANNING TO THE TEST REPORT

A clear process.
From start to finish.

Testing follows a defined process: initial information, agreed execution and documented findings. Here is how we work together.

01

Tell us about your site

We review your testing needs, equipment and preferred schedule.

02

Agree on the scope

We define the scope, practical arrangements and quotation.

03

Carry out the tests

We perform the agreed measurements and verify protection performance.

04

Receive clear results

We deliver the test report and review any findings.

CONTACT US ONLINE Review before sending

Your next step.
Just a few clicks away.

Prepare a service request or ask an expert. Review the summary, download a copy if you wish, and send your details to us.

The Send button submits your message. The scope of work and delivery date are confirmed separately.

GOOD TO KNOW

Frequently asked questions.

The first step is a shared
understanding of your site's needs.

Tell us the site location, protection relay manufacturer and model, number of relays and preferred timing. Settings, single-line diagrams and previous test reports help us plan the work. If some information is not yet available, we can clarify the scope together.

LET'S START WITH YOUR SITE

Confidence begins
with a conversation.

Tell us the site, relay types and preferred schedule. Together, we can plan the testing you need and how to deliver it.

Avitor's expert services
You can also specify a date range or deadline.
RELEKOESTUS

Request an equipment purchase quotation.

Check the details before sending. Availability, price and terms will be confirmed separately; this enquiry does not place an order or booking.

  1. 01Contact details
  2. 02Review
YOUR SELECTION

Kingsine equipment · Equipment purchase

Price and availability will be agreed separately.

Provider: Vitkala Group Oy

Selection details
Provider
Vitkala Group Oy
Product
Kingsine equipment
Enquiry type
Equipment purchase

Price and availability will be agreed separately.

Fields marked with an asterisk (*) are required.